SKILL

fda-qsr-audit-prep

Use for /compliance-os:fda-qsr-audit-prep, or before an FDA inspection, QMSR internal audit or Form 483 response.

Target: Target not categorized. Automatically collected · unverified.

Excerpt from the author’s documentation

Extracted from a fixed version of SKILL.md in its original language. This is the author’s documentation; installation, compatibility and runtime results have not been verified by this site.

Read the original English text

Topics in the source

  • /compliance-os:fda-qsr-audit-prep — FDA QSR Forcing Questions
  • When to Run
  • The Six QSR Questions
  • 1. Show me the complaint files from the last quarter — and the corresponding MDR reports.
  • 2. When was process validation (IQ/OQ/PQ) last revalidated per 21 CFR 820.75?
  • 3. Show me the DHRs for products commercially distributed in last 2 years.
  • 4. Show me CAPAs from the last 6 months with effectiveness verification.
  • 5. Show me labeling (21 CFR 801) review for the most recent product launch.

Command: /compliance-os:fda-qsr-audit-prep The FDA QSR auditor pressure-tests any US medical-device QSR work. Six questions before any internal audit, FDA inspection, Form 483 response, or recall decision. Before annual internal QSR audit Before pre-FDA-inspection readiness review (any device commercially distributed in US) After receiving Form 483 observations After Warning Letter receipt After MDR-reportable event Before recall decision (voluntary vs FDA-initiated) Before submitting 510(k) / PMA (where QSR posture affects approval timeline) 21 CFR 820.198 + 21 CFR 803 — most-cited FDA inspection area. Complaint log complete: who / what / when / device / batch Investigation closure within reasonable timeline MDR-reporting decision tree applied: death OR serious injury OR malfunction-that-could-cause = MDR 30-day timeline for most MDR reports; 5 days for certain serious events Complaint trending input to management review Cross-walks ISO 13485 Clause 7.5.6 (substantially harmonized post-Feb 2026). Initial validation at process introduction Revalidation triggers: process / equipment / material change OR periodic schedule Statistical techniques per 21 CFR 820.250 where applicable Cro

This is an excerpt. Refer to the complete source and its current requirements.

Source repository
alirezarezvani/claude-skills
Source file
compliance-os/skills/fda-qsr-audit-prep/SKILL.md
Fixed revision
8f082544116fc0d014188e521ca40304cdfc86b0
Read the complete original documentation ↗

Requirements

  • Only the author’s Skill metadata is included. Read the full instructions to check dependencies, licensing and conditions of use.

A small first task

先阅读原作者说明,再决定是否在自己的 AI 工具中使用。

Instructions for your AI tool

Author documentation is not live verification by this site. Without evidence, we do not mark a resource as compatible, safe or free.

Sources and evidence

This record was collected automatically. Its documentation, suitability and runtime behavior have not been manually verified.

Author: alirezarezvani/claude-skills · original repository metadata. Documentation review: Not reviewed. Last source check: 2026-11-09T14:01:46.305Z.

Categories are inferred from names, descriptions and paths. They do not establish compatibility.

License and attribution

MIT. Third-party content and copyright remain with their authors. Refer to the original license and terms.

Original license ↗

Synchronization, copying and user-reported success do not mark a resource as runtime-tested.

Limitations and notes

  • Collecting metadata does not mean this site has installed, adapted, runtime-tested or security-reviewed the resource.